DEHNguard modular (Y)PV SCI ...
- Prewired modular complete unit for use in photovoltaic systems consisting of a base part and plug-in protection modules
- Combined disconnection and short-circuiting device with safe electrical isolation in the protection module (patented SCI principle)
- Tried and tested fault-resistant Y circuit of DEHNguard M YPV SCI ... (FM) prevents damage to the surge protective device in case of insulation faults in the generator circuit
- Tested to EN 61643-31
- Suitable for use in all PV systems according to IEC 60364-7-712
DEHNguard M YPV SCI ...
GTIN: 4013364136663, customs tariff number: 85363030, gross weight: 0.29 KG, packaging unit: 1 ST
Modular and pluggable multipole arrester
for use in photovoltaic systems up to 150 V d.c.
with three-step d.c. switching device, width: 3 modules
Fault indication
Type 2 SPD according to EN 50539-11
For use in accordance with IEC 60364-7-712
Safe electrical isolation in the protection module
Max. PV voltage: <= 150 V d.c.
Total discharge current: 40 kA
Voltage protection level: <= 0.8 kV
Short-circuit current rating Iscpv: 10 kA
Brand: DEHN
Type: DG M YPV SCI 150
Part No.: 952513
or equivalent.
DEHNguard M YPV SCI ...
GTIN: 4013364126428, customs tariff number: 85363030, gross weight: 0.361 KG, packaging unit: 1 ST
Modular and pluggable multipole arrester
for use in photovoltaic systems up to 1000 V d.c.
with three-step d.c. switching device, width: 3 modules
Type 2 SPD according to EN 61643-31
For use in accordance with IEC 60364-7-712
Safe electrical isolation in the protection module
Max. PV voltage: <= 1000 V d.c.
Total discharge current: 40 kA
Voltage protection level: <= 4 kV
Short-circuit current rating Iscpv: 10 kA
Brand: DEHN
Type: DG M YPV SCI 1000
Part No.: 952510
or equivalent.
DEHNguard M YPV SCI ...
GTIN: 4013364127951, customs tariff number: 85354000, gross weight: 0.357 KG, packaging unit: 1 ST
Modular and pluggable multipole arrester
for use in photovoltaic systems up to 1200 V d.c.
with three-step d.c. switching device, width: 3 modules
Type 2 SPD according to EN 61643-31
For use in accordance with IEC 60364-7-712
Safe electrical isolation in the protection module
Max. PV voltage: <= 1200 V d.c.
Total discharge current: 30 kA
Voltage protection level: <= 4.5 kV
Short-circuit current rating Iscpv: 10 kA
Brand: DEHN
Type: DG M YPV SCI 1200
Part No.: 952512
or equivalent.
DEHNguard M YPV SCI ... FM
GTIN: 4013364136670, customs tariff number: 85363030, gross weight: 0.297 KG, packaging unit: 1 ST
Modular and pluggable multipole arrester
for use in photovoltaic systems up to 150 V d.c.
with three-step d.c. switching device, width: 3 modules
Fault indication
with remote signalling contact
Type 2 SPD according to EN 50539-11
For use in accordance with IEC 60364-7-712
Safe electrical isolation in the protection module
Max. PV voltage: <= 150 V d.c.
Total discharge current: 40 kA
Voltage protection level: <= 0.8 kV
Short-circuit current rating Iscpv: 10 kA
Brand: DEHN
Type: DG M YPV SCI 150 FM
Part No.: 952518
or equivalent.
DEHNguard M YPV SCI ... FM
GTIN: 4013364126435, customs tariff number: 85363030, gross weight: 0.344 KG, packaging unit: 1 ST
Modular and pluggable multipole arrester
for use in photovoltaic systems up to 1000 V d.c.
with three-step d.c. switching device, width: 3 modules
Fault indication
with remote signalling contact
Type 2 SPD according to EN 61643-31
For use in accordance with IEC 60364-7-712
Safe electrical isolation in the protection module
Max. PV voltage: <= 1000 V d.c.
Total discharge current: 40 kA
Voltage protection level: <= 4 kV
Short-circuit current rating Iscpv: 10 kA
Brand: DEHN
Type: DG M YPV SCI 1000 FM
Part No.: 952515
or equivalent.
DEHNguard M YPV SCI ... FM
GTIN: 4013364127968, customs tariff number: 85354000, gross weight: 0.359 KG, packaging unit: 1 ST
Modular and pluggable multipole arrester
for use in photovoltaic systems up to 1200 V d.c.,
width: 3 modules
Fault indication
with remote signalling contact
Type 2 SPD according to EN 61643-31
For use in accordance with IEC 60364-7-712
Safe electrical isolation in the protection module
Max. PV voltage: <= 1200 V d.c.
Total discharge current: 30 kA
Voltage protection level: <= 4.5 kV
Short-circuit current rating Iscpv: 10 kA
Brand: DEHN
Type: DG M YPV SCI 1200 FM
Part No.: 952517
or equivalent.
DEHNguard M PV2 SCI ... (FM)
GTIN: 4013364224964, customs tariff number: 85363030, gross weight: 0.588 KG, packaging unit: 1 ST
Modular and pluggable multipole arrester
for use in photovoltaic systems up to 1000 V d.c.
with three-step d.c. switching device, width: 5 modules
Fault indication
Type 2 SPD according to EN 61643-31
For use in accordance with IEC 60364-7-712
For protecting 2 MPP inputs
Safe electrical isolation in the protection module
Max. PV voltage: <= 1000 V d.c.
Total discharge current: 40 kA
Voltage protection level: <= 4 kV
Short-circuit current rating Iscpv: 10 kA
Brand: DEHN
Type: DG M PV2 SCI 1000
Part No.: 952514
or equivalent.
DEHNguard M PV2 SCI ... (FM)
GTIN: 4013364224971, customs tariff number: 85363030, gross weight: 0.599 KG, packaging unit: 1 ST
Modular and pluggable multipole arrester
for use in photovoltaic systems up to 1000 V d.c.
with three-step d.c. switching device
with remote signalling contact, width: 5 modules
Fault indication
Type 2 SPD according to EN 61643-31
For use in accordance with IEC 60364-7-712
For protecting 2 MPP inputs
Safe electrical isolation in the protection module
Max. PV voltage: <= 1000 V d.c.
Total discharge current: 40 kA
Voltage protection level: <= 4 kV
Short-circuit current rating Iscpv: 10 kA
Brand: DEHN
Type: DG M PV2 SCI 1000 FM
Part No.: 952519
or equivalent.
DEHNguard M SN1868
GTIN: 4013364328723, customs tariff number: 85363030, gross weight: 0.598 KG, packaging unit: 1 ST
Modular and pluggable multipole arrester for use in photovoltaic systems up to 1000 V d.c.
with three-step d.c. switching device
with remote signalling contact, width: 5 modules
Type 2 SPD according to EN 61643-31
For use in accordance with IEC 60364-7-712
For protecting 3 MPP inputs
Safe electrical isolation in the protection module
Max. PV voltage: <= 1000 V d.c.
Total discharge current: 40 kA
Voltage protection level: <= 4 kV
Short-circuit current rating Iscpv: 10 kA
Fault indication
Brand: DEHN
Type: DG M PV2 SCI SN1868 FM
Part No.: 999799
or equivalent.