EXFS 100 / EXFS 100 KU
- For indirect connection / earthing of functionally isolated parts of installations under lightning conditions
- Device for lightning equipotential bonding according to IEC 62305 in hazardous areas
- For bridging insulating joints, insulating flanges, etc. in cathodically protected pipe sections
- For safe installation in Ex zone 1 (gas) or 21 (dust)
- Extremely low sparkover voltage
- Extremely high alternating current withstand capability
- Approval according to ATEX directive 2014/34/EU, IECEx, UL and Inmetro
EXFS 100: Connecting Cable, Cu, 25 mm²
Connecting cable for EXFS 100; two cable lugs (Ø10.5 mm) made of Cu/gal Sn, screw, nut and spring washer.
Part No. 923025
AL EXFS L100 KS
item
EXFS 100: Connecting Cable, Cu, 25 mm²
Connecting cable for EXFS 100; two cable lugs (Ø10.5 mm) made of Cu/gal Sn, screw, nut and spring washer.
Part No. 923045
AL EXFS L300 KS
item
EXFS 100: Connecting Cable, Cu, 25 mm²
Connecting cable for EXFS 100; two cable lugs (Ø10.5 mm) made of Cu/gal Sn, screw, nut and spring washer.
Part No. 923035
AL EXFS L200 KS
item
EXFS 100
Isolating spark gap for use in hazardous areas with plastic sheath and M10 threaded screws.
Part No. 923100
EXFS 100
item
GTIN: 4013364108325, customs tariff number: 85369010, gross weight: 0.309 KG, packaging unit: 1 ST
EXFS 100 isolating spark gap
EXFS 100 isolating spark gap according to IEC 62561-3:2011 (81/387/CDV) / EN 62561-3
for lightning equipotential bonding according to IEC 62305-3,
particularly for use in potentially explosive atmospheres up to zone 1 or 21
IECEx / ATEX certification (2014/34/EU)
Ex marking according to
IEC / EN 60079: Gas II 2G Ex d IIC T6
IEC / EN 61241: Dust II 2D Ex tD A21 IP67 T 80°C
Lightning impulse current (10/350): 100 kA
Class of lightning current carrying capability acc. to IEC 62561-3: 2011 (81/387/CDV) / EN 62561-3: H
Nominal discharge current (8/20): 100 kA
Rated impulse sparkover voltage: <= 1.25 kV
Power frequency sparkover voltage (50Hz): <= 0.5 kV
Rated power frequency withstand voltage (50 Hz): <= 250 V
Rated discharge current (50 Hz): 500 A / 0.2 sec. (Tu <= 45°C)
Degree of protection: IP67
Enclosure: M10 x 25 screw and spring washer on both ends
Brand: DEHN
Type: EXFS 100
Part No.: 923100
or equivalent.
EXFS 100 isolating spark gap according to IEC 62561-3:2011 (81/387/CDV) / EN 62561-3
for lightning equipotential bonding according to IEC 62305-3,
particularly for use in potentially explosive atmospheres up to zone 1 or 21
IECEx / ATEX certification (2014/34/EU)
Ex marking according to
IEC / EN 60079: Gas II 2G Ex d IIC T6
IEC / EN 61241: Dust II 2D Ex tD A21 IP67 T 80°C
Lightning impulse current (10/350): 100 kA
Class of lightning current carrying capability acc. to IEC 62561-3: 2011 (81/387/CDV) / EN 62561-3: H
Nominal discharge current (8/20): 100 kA
Rated impulse sparkover voltage: <= 1.25 kV
Power frequency sparkover voltage (50Hz): <= 0.5 kV
Rated power frequency withstand voltage (50 Hz): <= 250 V
Rated discharge current (50 Hz): 500 A / 0.2 sec. (Tu <= 45°C)
Degree of protection: IP67
Enclosure: M10 x 25 screw and spring washer on both ends
Brand: DEHN
Type: EXFS 100
Part No.: 923100
or equivalent.
EXFS 100 KU
Iisolating spark gap EXFS 100 KU with connecting cable for aboveground and underground installation; with water-proof sheath; can be shortened for short connecting cables.
Part No. 923101
EXFS 100 KU
item
GTIN: 4013364108332, customs tariff number: 85369095, gross weight: 2.14 KG, packaging unit: 1 ST
Isolating spark gap EXFS 100 KU
Isolating spark gap EXFS 100 KU according to IEC 62561-3:2011 (81/387/CDV) / EN 62561-3
for lightning equipotential bonding according (protection of insulation) acc. to IEC 62305-3,
particularly for use in potentially explosive atmospheres up to zone 1 / 21,
with connecting cables for aboveground and underground installation
IECEx / ATEX certification (2014/34/EU)
Ex marking according to
IEC / EN 60079: Gas II 2G Ex d IIC T6
IEC / EN 61241: Dust II 2D Ex tD A21 IP67 T 80°C
Lightning impulse current (10/350): 100 kA
Class of lightning current carrying capability acc. to IEC 62561-3:2011 (81/387/CDV) / EN 62561-3: H
Nominal discharge current (8/20): 100 kA
Rated impulse sparkover voltage: <= 1.25 kV
Power frequency sparkover voltage (50Hz): <= 0.5 kV
Rated power frequency withstand voltage (50 Hz): <= 250 V
Rated discharge current (50 Hz):
500 A / 0.2 sec. (Tu <= 45°C)
Degree of protection: IP67
Water-proof plastic coating
Cable: NYY-J 1 x 25 mm2 on both ends, approx. 2 m long
Brand: DEHN
Type: EXFS 100 KU
Part No.: 923101
or equivalent.
Isolating spark gap EXFS 100 KU according to IEC 62561-3:2011 (81/387/CDV) / EN 62561-3
for lightning equipotential bonding according (protection of insulation) acc. to IEC 62305-3,
particularly for use in potentially explosive atmospheres up to zone 1 / 21,
with connecting cables for aboveground and underground installation
IECEx / ATEX certification (2014/34/EU)
Ex marking according to
IEC / EN 60079: Gas II 2G Ex d IIC T6
IEC / EN 61241: Dust II 2D Ex tD A21 IP67 T 80°C
Lightning impulse current (10/350): 100 kA
Class of lightning current carrying capability acc. to IEC 62561-3:2011 (81/387/CDV) / EN 62561-3: H
Nominal discharge current (8/20): 100 kA
Rated impulse sparkover voltage: <= 1.25 kV
Power frequency sparkover voltage (50Hz): <= 0.5 kV
Rated power frequency withstand voltage (50 Hz): <= 250 V
Rated discharge current (50 Hz):
500 A / 0.2 sec. (Tu <= 45°C)
Degree of protection: IP67
Water-proof plastic coating
Cable: NYY-J 1 x 25 mm2 on both ends, approx. 2 m long
Brand: DEHN
Type: EXFS 100 KU
Part No.: 923101
or equivalent.